| DC Voltage Ranges: |
|
400 mV, 4 V, 40 V, 400 V, 1000 V |
| DC Voltage Accuracy: |
|
all ranges: ± (0.5 % rdg + 1 dgt) |
| DC Voltage Resolution: |
|
100 μV |
| AC Voltage (45 Hz to 2 kHz) True RMS Ranges: |
|
400 mV, 4 V, 40 V, 400 V, 750 V |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: |
|
400 mV range, 45 to 100 Hz: ± (1.2 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: |
|
750 V range: 45 to 1 kHz: ± (2.0 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: |
|
All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: |
|
All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Resolution: |
|
100 μV |
| DC Current Ranges: |
|
400 μA, 4 mA, 40 mA, 300 mA, 10 A |
| DC Current Accuracy: |
|
400 μA to 300 mA ranges: ± (1.0 % rdg + 1 dgt) |
| DC Current Accuracy: |
|
10 A range: ± (2.0 % rdg + 3 dgts) |
| DC Current Resolution: |
|
0.1 μA |
| DC Current Voltage Burden: |
|
400 μA range: 1 mV/μA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA, |
| DC Current Voltage Burden: |
|
400 μA, 4 mA, 40 mA, 300 mA, 10 A |
| AC Current (45 Hz to 1 kHz) True RMS Ranges: |
|
400 μA, 4 mA, 40 mA, 300 mA, 10 A |
| AC Current (45 Hz to 1 kHz) True RMS Accuracy: |
|
400 μA to 300 mA ranges: ± (1.5 % rdg + 8 dgts) |
| AC Current (45 Hz to 1 kHz) True RMS Accuracy: |
|
10 A range: ± (2.5 % rdg + 10 dgts) |
| AC Current (45 Hz to 1 kHz) True RMS Resolution: |
|
0.1 μA |
| Resistance Ranges: |
|
400 Ω 4 kΩ 40 kΩ 400 kΩ 4 MΩ 40 MΩ |
| Resistance Accuracy: |
|
400, 4 k, 40 k, 400 k, 4 MΩ ranges: ± (1.0 % rdg + 4 dgts) |
| Resistance Accuracy: |
|
40 MΩ range: ± (2.0 % rdg + 5 dgts) |
| Resistance Resolution: |
|
100 mΩ |
| Continuity Audible Indication: |
|
< 35 Ω |